Notes on Gas Sensors and Detectors.

Gas detectors and gas sensors interact with a gas to initiate the measurement of its concentration. The gas detector of gas sensor then provides output to a gas instrument to display the measurements. Common gases measured by gas detectors and gas sensors include ammonia, aerosols, arsine, bromine, carbon dioxide, carbon monoxide, chlorine, chlorine dioxide, Diborane, dust, fluorine, germane, halocarbons or refrigerants, hydrocarbons, hydrogen, hydrogen chloride, hydrogen cyanide, hydrogen fluoride, hydrogen selenide, hydrogen sulfide, mercury vapor, nitrogen dioxide, nitrogen oxides, nitric oxide, organic solvents, oxygen, ozone, phosphine, silane, sulfur dioxide, and water vapor.

Important measurement specifications to consider when looking for gas detectors and gas sensors include the response time, the distance, and the flow rate. The response time is the amount of time required from the initial contact with the gas to the sensors processing of the signal. Distance is the maximum distance from the leak or gas source that the sensor can detect gases. The flow rate is the necessary flow rate of air or gas across the gas detectors or gas sensors to produce a signal.

Gas detectors and gas sensors can output a measurement of the gases detected in a number of ways. These include percent LEL, percent volume, trace, leakage, consumption, density, and signature or spectra. The lower explosive limit (LEL) or lower flammable limit (LFL) of a combustible gas is defined as the smallest amount of the gas that will support a self-propagating flame when mixed with air (or oxygen) and ignited. In gas-detection systems, the amount of gas present is specified in terms of % LEL: 0% LEL being a combustible gas-free atmosphere and 100% LEL being an atmosphere in which the gas is at its lower flammable limit. The relationship between % LEL and % by volume differs from gas to gas. Also called volume percent or percent by volume, percent volume is typically only used for mixtures of liquids. Percent by volume is simply the volume of the solute divided by the sum of the volumes of the other components multiplied by 100%. Trace gas sensors given in units of concentration: ppm. Leakage is given as a flow rate like ml/min. Consumption may also be called respiration. Given in units of ml/L/hr. Density measurements are given in units of density: mg/m^3. A signature or spectra measurement is a spectral signature of the gases present; the output is often a chromatogram.

Common outputs from gas detectors and gas sensors include analog voltage, pulse signals, analog currents and switch or relays. Operating parameters that are important to consider for gas detectors and gas sensors include operating temperature and humidity.


With Regards,

Sebastian

G.M. Technical

Nunes Instruments

645 Hundred Feet Road,

Coimbatore. 641012.

Tamil Nadu

India,

Web: www.nunesinstruments.com

Mail: info@nunesinstruments.com



Mobile: 09345226022

No comments: